;********************************************************************* ; ; GSD-File for PB251 ; ; File: mksr0635.gsd ; Version: 05 ; Date: 07.01.2008 ; Author: Thomas Jaeckle ; ; motrona GmbH ; Zwischen den Wegen 32 ; 78239 Rielasingen - GERMANY ; Tel.: ++49-7731-9332-0 Fax: ++49-7731-9332-30 ; Email: thomas.jaeckle@motrona.com ; ;********************************************************************* ; #Profibus_DP ; ;General parameters: ; GSD_Revision = 3 Vendor_Name = "motrona" Model_Name = "PB251" Revision = "01" Ident_Number = 0x0635 Protocol_Ident = 0 ; Profibus-DP Station_Type = 0 ; Slave FMS_supp = 0 ; No FMS supported Hardware_Release = "01" Software_Release = "01" ; 9.6_supp = 1 ; Supported baudrates 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 ; Redundancy = 0 Repeater_Ctrl_Sig = 2 ; RTS-Signal (CNTR-P): TTL-level 24V_Pins = 0 ; No 24V supply on Profibus-connector Implementation_Type = "DPC31" ; ; ; Slave-Specification: ; Freeze_Mode_supp = 1 ; Freeze-Mode supported Sync_Mode_supp = 1 ; Sync-Mode supported Set_Slave_Add_Supp = 0 ; Set_Slave_Address not supported Auto_Baud_supp = 1 ; Automatic baudrate recognition Min_Slave_Intervall = 6 Fail_Safe = 1 ; Fail-Save-Mode supported ; Max_Diag_Data_Len = 11 ; 5 byte user diagnostic data Modul_Offset = 0 Slave_Family = 9 ; Gateway Modular_Station = 1 Max_Module = 1 ; Modular station with one module Max_Input_len = 4 ; max. 4 byte input data Max_Output_len = 4 ; max. 4 byte output data Max_Data_len = 8 ; max. 2 * 4 byte data ; ; ; UserPrmData: ; Max_User_Prm_Data_Len = 8 ; 3 byte DPV1 parameter + 5 byte user parameter data ; ; ; ExtUserPrmData = 1 "Cycl. Req. Param." ; User parameter Unsigned16 0 0-0x7fff ; Type, default value, value range EndExtUserPrmData ; ExtUserPrmData = 2 "Cycl. Send Param." ; User parameter Unsigned16 0 0-0x7fff ; Type, default value, value range EndExtUserPrmData ; ExtUserPrmData = 3 "Serial Mode" ; User parameter Unsigned8 1 1-5 ; Type, default value, value range EndExtUserPrmData ; Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x00 ; 3 byte DPV1 parameter Ext_User_Prm_Data_Const(3) = 0x00, 0x00, 0x00, 0x00, 0x00 ; 5 byte user parameter Ext_User_Prm_Data_Ref(3) = 1 Ext_User_Prm_Data_Ref(5) = 2 Ext_User_Prm_Data_Ref(7) = 3 ; ; ; Module Definition List (Configuration): ; Module="Cyclic Read and Write" 0xB3 ; 4 byte input data + 4 byte output data 1 EndModule Module="Cyclic Read only" 0x93 ; 4 byte input data, no output data 2 EndModule ; ; ; DPV1: ; DPV1_Slave = 1 C1_Read_Write_supp = 1 C2_Read_Write_supp = 1 C1_Max_Data_Len = 240 C2_Max_Data_Len = 240 C1_Response_Timeout = 100 ; in units of 10ms, optional C2_Response_Timeout = 100 ; in units of 10ms, optional C1_Read_Write_required = 0 C2_Read_Write_required = 0 C2_Max_Count_Channels = 1 Max_Initiate_PDU_Length = 64 Diagnostic_Alarm_supp = 0 Process_Alarm_supp = 0 Pull_Plug_Alarm_supp = 0 Status_Alarm_supp = 0 Update_Alarm_supp = 0 Manufacturer_Specific_Alarm_supp = 0 Extra_Alarm_SAP_supp = 0 Alarm_Sequence_Mode_Count = 0 Alarm_Type_Mode_supp = 0 Diagnostic_Alarm_required = 0 Process_Alarm_required = 0 Pull_Plug_Alarm_required = 0 Status_Alarm_required = 0 Update_Alarm_required = 0 Manufacturer_Specific_Alarm_required = 0 ; DPV1_Data_Types = 0 ; optional WD_Base_1ms_supp = 1 Check_Cfg_Mode = 0 ; ;--------------------------------------------------------------------